Verify that the electrical switch is in the “Off” position and connected to a power source.
Measure the voltage across the switch by placing the voltmeter probes across the input and output terminals of the switch. Turn the switch to the “On” position and read the value on the voltmeter. This is the voltage across the switch. Write this value down.
Determine the maximum current that the switch can handle. This data is contained in the data sheet for the switch.
Calculate the minimum value for the resistor in the RC snubber by dividing the voltage across the switch by the maximum current rating. For example, suppose the voltage measurement is 160 volts and the maximum current is 5 amps. Dividing 160 volts by 5 amps gives you 32 ohms. Your snubber must use a resistor that has a minimum resistance of 32 ohms.
Determine the switching frequency, in switches per second. For example, suppose the switch changes states 50,000 times per second, or 50 KHz. This value is determined by the designers of the circuit, and should be available in the circuit documentation.
Calculate the capacitance for the snubber by multiplying the switching frequency by the squared value of the voltage measurement acquired in Step 2. Take the inverse of this number (i.e. divide 1 by the value). For example, given a switching frequency of 50 KHz and a voltage of 160 volts, your equation looks like this:
C = 1 / (160^2)*50,000 = 780 pF